Share via email
Some fields are missing
Bürkert - Close to you
Office /1
    • Main Office
      Burkert Japan Ltd.
      Shiratoribashi Mikasa-building
      1-12-15 Suido, Bunkyo-ku,
      Tokyo 112-0005
      電話番号 +81 35804 5020
      Fax +81 35804 5021
      E-Mail vasb.wca@ohexreg.pbz
      Website http://www.burkert.jp/
  • Main Office
  • Headquarters
  • Systemhaus
  • Distributor
  • Office
  • Plant
  • Logistic center
bürkert
 

    AirLINE Exのタイプ8650は、爆発の危険性がある領域(区分1/21)向けのモジュール式電空オートメーションシステムです。

    Type 8650 / Ident No. 246528

    Compare now 印刷
    Produkt-Foto Typ 8650

    The depiction of the products may differ from the actual specific design.

    • Produkt-Foto Typ 8650
    • Produkt-Foto Typ 8650

    Valve block 8650 Ex 24-bank 6524/6525

    • 爆発の危険性がある領域(区分1/21)への使用向けに設計
    • Siemens Automation and Drives社との協力開発
    • Siemens SIMATIC ET 200 iSP™ モジュール経由のPROFIBUS® DP-is(電子式I/O機能)による電気制御

    For selecting the correct product please refer to the technical data, images and notes for proper use according to the data sheet.

    Product description

    AirLINE Ex タイプ8650は、爆発の危険性がある環境(区分1/21)における複雑なプロセス/製造過程 を制御する、モジュール式電空オートメーションシステムです。電子回路モジュールおよびバルブの点火保護方式は“本質安全”(Ex-i) であるため、運転中の交換が可能です。提携パートナーであるSiemensのモジュールを用いて、電子式、アナログ式、デジタル式のI/O機能を区分0用にも使用することが可能です。一括システムには、シリアル化データと共にSDカード上のデータセットも同梱されています。


    Commodity Codes
    84812090
    国名
    DE

    Technical attributes

    名前
    Value
    Unit
    Type 8650
    Product sub-group Valve islands & automation systems
    Add-on dimension 1 11 mm
    modular version without (due to block design)
    Mounting type DIN-rail installation
    Internal bus communication combinable with Siemens
    Valve function different valves assembled
    Supply connection G 3/8
    Working connection D6
    Working connection position Bottom (pneumatic module)
    Integrated check valves in 5 (S) No
    Integrated check valves in 3 (R) No
    Pneumatic HotSwap in 1 (P) No
    Intermediate feed quantity 1 PCE
    Manometer Yes
    Manometer quantity 1 PCE
    Manual/Automatic switching No
    Input type digital quantity 0 PCE
    Nominal pressure min 2,5 bar
    Nominal pressure max 7 bar
    Temperature environment min 0 °C
    Temperature environment max 55 °C
    Temperature medium min 0 °C
    Temperature medium max 50 °C
    Protection type (IP max. with suitable connector) IP30
    Weight 4,477000 kg
    Approval type
    Certification type , ,
    Show full table Collapse table

    Downloads

    Data Sheets

    説明
    Filesize
    Language / Country
    DTS Type 8650 data sheet | modular electrical/pneumatic automation system AirLINE Ex 4 MB EN / EU
    DTS Type 8650 data sheet | modular electrical/pneumatic automation system AirLINE Ex [v.US] 3 MB EN / US
    DTS Typ 8650 Datenblatt | modulares Automatisierungssystem AirLINE Ex 4 MB DE / DE

    User Manuals

    説明
    Filesize
    Language / Country
    MAN Operating Instructions Type 8650 | AirLINE Ex - Electrical and pneumatic automation system 10 MB EN / EU
    MAN Quickstart Type 8650 | AirLINE Ex - Electrical and pneumatic automation system 3 MB EN / EU
    MAN Software manual Type 8644 | Configuration on the PROFIBUS by means of GSD file 4 MB EN,FR,DE / EU
    MAN Bedienungsanleitung Typ 8650 | AirLINE Ex, elekt. und pneumatisches Automatisierungssystem 10 MB DE / DE
    MAN Manuel d'utilisation Type 8650 | AirLINE Ex, Système d?automatisation électr. et pneum. 10 MB FR / FR
    MAN Quickstart Typ 8650 | AirLINE Ex - Elektrisches und pneumatisches Automatisierungssystem 3 MB DE / DE

    Software

    説明
    Filesize
    Language / Country
    SOW EDD File A.00 1 kB ML
    SOW GSD File A.00 1 kB ML
    SOW Initiation files SUP and HSP 2.6 4 MB ML
    SOW Installation Files PCS7 1.0 9 MB ML

    EU Declaration of Conformity

    説明
    Filesize
    Language / Country
    ABD EU-DoC|EU Declaration 2 MB EN,FR,DE

    Flyers and Catalogues

    説明
    Filesize
    Language / Country
    MISC Automation System, Type 8650, AirLINE Ex 166 kB EN / DE
    MISC Flyer Best Practice - Automation with valve islands and remote I/O systems for chemical plants of the future for the F3 Factory Project. 493 kB EN / GB
    MISC Flyer Best Practice Plant modernization in an explosion protection environment 1 MB EN / EU

    My Comparison List